AutoPure Pilot600 Protein Purification System

AutoPure Pilot600 Protein Purification System

Product Introduction

Unique AutoPure Pilot600 features rich configurations and high cost-effectiveness. The system utilizes the powerful Unique CDSystem chromatography workstation, which supports bilingual language switching between Chinese and English. It has a user-friendly interface, intelligent programming, and easy-to-use operation. Real-time online data monitoring and system control are available. The visual flow diagram provides intuitive visibility of system parameters and integrates shortcut commands. Additionally, professional and timely after-sales service is offered to alleviate customer concerns.

Features

● Flexible configuration, supporting chromatography column specifications from 26 mm to 200 mm in diameter.

● Compact design for convenient operation.

● Human-machine interactive operating interface for simplified operation and automation editing.

● High-precision plunger pump ensures stable flow rates and gradients.

● Comprehensive software functionality with high automation levels.

Product Parameter:

ConfigurationUnique AutoPilot600
System Pump (Dual Pump System)A/B Pump
Flow Rate Range: 1 ~ 600 ml/min (Dual Pump Stack Column Mode: 1 ~ 1200 ml/min)
Qualified Range: 5% ~ 95%
Main System Dimensions (LWH)600mm*500mm*850mm
Main System Weight65kg
Control SystemUnique CDSystem
Enclosure Protection LevelIP23
Power Supply100~240 V~, 50~60 Hz
Operating EnvironmentOperating Environment: Temperature: 5℃ ~ 35℃, Relative Humidity: 20%RH ~ 80%RH
UV DetectorUV Detector: 280 nm Fixed Wavelength Detector
LED Light Source, Lifespan > 8000 h
DAD Full Spectrum Direct Reading Detector: Variable Dual Wavelength 200 ~ 400 nm
Fiber Optic Transmission, External Flow Cell, Prevents Light Source Temperature from Affecting Protein Sample Activity, Dual Beam Design with High Stability.
Conductivity DetectorDisplay Range: 0.1 mS/cm ~ 999.9 mS/cm
Built-in Temperature Sensor, Automatic Conductivity Compensation Calibration
Temperature DetectorTemperature Range: 0 ~ 99℃;
pH DetectorDisplay Range: 0 ~ 14;
Inlet SelectionSingle Pump with 4 Inlets, Dual Pump with a Total of 8 Inlets, Expandable to 12 Inlets
Outlet Selection4 Outlets, Expandable to 8 Outlets
Column Position ValveSingle Column Position, Cannot Forward/Reverse Flush
Bubble TrapEffectively Removes Bubbles in the System, Available Online or Offline
MixerMixer Chamber Volume: 12 ml
Bubble SensorSupports Up to 3
Pressure Sensor1 System Pressure Sensor, 1 Pre-column Pressure Sensor, and 1 Post-column Pressure Sensor (Optional), Detection Range: 0-2 MPa

Our Certificate

滚动至顶部