AutoPure Pilot600 Protein Purification System

Product Introduction
Unique AutoPure Pilot600 features rich configurations and high cost-effectiveness. The system utilizes the powerful Unique CDSystem chromatography workstation, which supports bilingual language switching between Chinese and English. It has a user-friendly interface, intelligent programming, and easy-to-use operation. Real-time online data monitoring and system control are available. The visual flow diagram provides intuitive visibility of system parameters and integrates shortcut commands. Additionally, professional and timely after-sales service is offered to alleviate customer concerns.
Features
● Flexible configuration, supporting chromatography column specifications from 26 mm to 200 mm in diameter.
● Compact design for convenient operation.
● Human-machine interactive operating interface for simplified operation and automation editing.
● High-precision plunger pump ensures stable flow rates and gradients.
● Comprehensive software functionality with high automation levels.
Product Parameter:
| Configuration | Unique AutoPilot600 |
| System Pump (Dual Pump System) | A/B Pump |
| Flow Rate Range: 1 ~ 600 ml/min (Dual Pump Stack Column Mode: 1 ~ 1200 ml/min) | |
| Qualified Range: 5% ~ 95% | |
| Main System Dimensions (LWH) | 600mm*500mm*850mm |
| Main System Weight | 65kg |
| Control System | Unique CDSystem |
| Enclosure Protection Level | IP23 |
| Power Supply | 100~240 V~, 50~60 Hz |
| Operating Environment | Operating Environment: Temperature: 5℃ ~ 35℃, Relative Humidity: 20%RH ~ 80%RH |
| UV Detector | UV Detector: 280 nm Fixed Wavelength Detector |
| LED Light Source, Lifespan > 8000 h | |
| DAD Full Spectrum Direct Reading Detector: Variable Dual Wavelength 200 ~ 400 nm | |
| Fiber Optic Transmission, External Flow Cell, Prevents Light Source Temperature from Affecting Protein Sample Activity, Dual Beam Design with High Stability. | |
| Conductivity Detector | Display Range: 0.1 mS/cm ~ 999.9 mS/cm |
| Built-in Temperature Sensor, Automatic Conductivity Compensation Calibration | |
| Temperature Detector | Temperature Range: 0 ~ 99℃; |
| pH Detector | Display Range: 0 ~ 14; |
| Inlet Selection | Single Pump with 4 Inlets, Dual Pump with a Total of 8 Inlets, Expandable to 12 Inlets |
| Outlet Selection | 4 Outlets, Expandable to 8 Outlets |
| Column Position Valve | Single Column Position, Cannot Forward/Reverse Flush |
| Bubble Trap | Effectively Removes Bubbles in the System, Available Online or Offline |
| Mixer | Mixer Chamber Volume: 12 ml |
| Bubble Sensor | Supports Up to 3 |
| Pressure Sensor | 1 System Pressure Sensor, 1 Pre-column Pressure Sensor, and 1 Post-column Pressure Sensor (Optional), Detection Range: 0-2 MPa |
Our Certificate